The TimePod Ultra 2™ is a two-person hard-shell hyperbaric chamber with manufacturer-listed pressure capability up to 2.0 ATA. Its shared seating layout, communication features and dual air and oxygen equipment are designed around a multi-occupant configuration. Picture a dedicated room planned around clear access, comfortable seating and trained attendance, rather than an improvised installation. Confirm medical suitability, supervision requirements and the complete supplied system before purchase.
Why Customers Choose This Product
- Listed capacity for two occupants.
- Stainless-steel and PC engineering-plastic hard-shell construction.
- Listed dual air handlers and dual oxygen concentrators.
- Call button and speaker functionality for communication.
- Host-platform cooling and dehumidification features.
- Single-unit or split delivery configurations described for site access.
Product Highlights
Two-Occupant Interior
The listing describes simultaneous occupancy by two users and references electrically adjustable seating. Confirm usable interior space, seating adjustment, occupant limits and accessibility with the manufacturer. Shared occupancy does not establish that either occupant can act as a trained attendant or that unsupervised use is appropriate.
Dual Air and Oxygen Equipment
Two air handlers and two oxygen concentrators are described using an OxyPrime-style host architecture. The host specifications reference oxygen flow settings of 5 and 10 L/min. Confirm each supplied unit's rating, oxygen delivery method and complete system compatibility; flow rates do not establish chamber oxygen concentration or therapeutic effectiveness.
Monitoring and Communication
The listed controls include a manual pressure-regulating valve, pressure gauge, emergency relief valve, call button and speaker. These features do not replace trained operation, required supervision or manufacturer emergency procedures. This description does not provide pressurization or decompression instructions.
Delivery Access Options
The chamber may be shipped as one completed unit or divided for on-site assembly, according to the description. Confirm exact section dimensions and whether split delivery is available for your order. Assembly and recommissioning must follow manufacturer procedures with appropriately qualified personnel.
Specifications
- Product: TimePod Ultra 2™.
- Listed base model: XH18220-2; confirm manufacturer and exact supplied model.
- Format: Two-person hard-shell hyperbaric chamber.
- Listed maximum pressure capability: 2.0 ATA.
- Listed chamber dimensions: 2200 × 1600 × 1700 mm, in the order supplied by the source.
- Listed chamber weight: 820 kg / approximately 1808 lb.
- Materials: Stainless steel and PC engineering plastics.
- Listed system configuration: Two air handlers and two oxygen concentrators.
- Host platform: All-in-one unit architecture.
- Listed host dimensions: 766 × 350 × 750 mm.
- Listed host weight: 110 kg / approximately 243 lb; confirm unit count and total system weight.
- Listed host airflow: 72 L/min; confirm whether per unit or total.
- Listed oxygen flow options: 5 and 10 L/min; confirm supplied settings and equipment.
- Filtration: Air and activated-carbon filter elements.
- Host functions described: Oxygen supply, air handling, filtration, anion function, cooling and dehumidification.
- Pressure controls: Manual regulating valve and emergency relief valve.
- Monitoring: Pressure gauge/barometer.
- Communication: Call button and speaker.
- Seating: Electrically adjustable positions referenced in manufacturer materials; confirm inclusion.
- Shipment options described: Completed unit or divided for on-site assembly.
The source's inch dimensions conflict with its millimeter dimensions. Obtain verified drawings, dimension order, entry clearances and sectional transport measurements before site planning. The source also lists an approximate 100 kPa pressure equivalent without defining absolute versus gauge pressure; use manufacturer documentation rather than this conversion. Electrical requirements, oxygen purity, chamber oxygen concentration, installed system weight and required operating clearances are not specified.
Ideal For
- Buyers comparing two-occupant chamber layouts with qualified professional guidance.
- Sites able to provide verified structural support, electrical provision and trained operation.
- Projects requiring planned freight access and manufacturer-directed commissioning.
Two-person capacity and a hard-shell structure do not establish medical suitability, home-use suitability or authorization for a particular clinical or commercial use.
Important Information
Seek guidance from a qualified healthcare professional experienced in hyperbaric care before purchase or use. Confirm the manufacturer's intended use, medical screening requirements, supervision, operator training and full operating documentation. A 2.0 ATA capability is not a recommended treatment setting; no pressure schedule, session duration or medical outcome is prescribed here.
Confirm the exact chamber, seating, host-unit count, oxygen equipment, delivery interfaces and any optional upgrades on a written build sheet. The original copy references an optional BIBS oxygen upgrade, but it is not assumed included or compatible without manufacturer confirmation. Do not add or modify oxygen-delivery or pressure equipment.
Have appropriately qualified professionals verify floor loading for the chamber, occupants and ancillary equipment, along with delivery route, foundation, electrical circuits, ventilation, fire precautions and installation requirements. Confirm permitted clothing, materials and electronics with the manufacturer. Do not assume that shared occupancy or internal controls makes unattended use appropriate.
Pressure regulation, emergency venting and door opening must follow trained manufacturer procedures. Do not use this listing as an operating guide. Follow approved cleaning, inspection, filter replacement and service schedules rather than assuming a generic interval applies to every configuration.
The source lists a two-year limited manufacturing-defect warranty for the chamber, controls, compressor, concentrator and dehumidifier, excluding normal wear, consumables and improper-use damage, while stating coverage varies. Confirm written coverage, exclusions and service arrangements before purchase. Freight, split assembly and white-glove installation are configuration- and destination-dependent; confirm current availability, costs and timing with Peak Repair Labs rather than assuming the source's support promises apply.
Frequently Asked Questions
How many occupants is the chamber listed for?
The TimePod Ultra 2 is listed for two occupants. Confirm seating, occupant limits, medical suitability and required supervision with the manufacturer and qualified professionals.
What pressure capability is listed?
The manufacturer-listed maximum capability is 2.0 ATA. This is not a recommended treatment setting or a session protocol.
What are the chamber dimensions?
The source lists 2200 × 1600 × 1700 mm, but its inch dimensions conflict. Obtain verified manufacturer drawings and dimension order before planning access or installation.
Can the chamber be divided for delivery?
The description offers completed-unit or divided delivery for on-site assembly. Confirm availability, section dimensions and qualified assembly and commissioning arrangements for your order.
What air and oxygen equipment is described?
The listing describes two air handlers and two oxygen concentrators, with host oxygen flow options of 5 and 10 L/min. Confirm the exact equipment, per-unit ratings and delivery method on the build sheet.
Can two users operate it without an attendant?
Shared occupancy does not establish suitability for unattended use. Confirm required supervision, operator training and emergency procedures before use.
What warranty is listed?
The source lists a two-year limited manufacturing-defect warranty on the chamber and specified system components, with exclusions and configuration-dependent coverage. Confirm the full written terms and service arrangements before purchase.
Confirm the verified dimensions, complete equipment package and professional-use requirements before choosing the TimePod Ultra 2 for your space.
SEO Title and Meta Description
SEO title: TimePod Ultra 2 Hyperbaric Chamber | Peak Repair Labs
Meta description: Explore the TimePod Ultra 2 two-person hard-shell hyperbaric chamber with listed 2.0 ATA capability, dual air handling and oxygen equipment. Peak Repair Labs.
This description is informational and does not establish medical suitability, therapeutic effectiveness or a treatment protocol. Consult a qualified healthcare professional experienced in hyperbaric care and follow manufacturer instructions before use.